CUSTODY TRANSFER GAS FLOW MEASUREMENT AND PROCESS MONITORING

Technical Data:

Measured values Volumetric flow, a. c., volume a. c., gas velocity, sound velocity
Number of measuring paths 2, 4, 4+1, 4+4
Measurement principle Ultrasonic transit time difference measurement
Measuring medium Natural gas, air, C 2 H 4 , steam, process gases (e. g. CO 2 up to 100%, N 2 , O 2 , Cl 2 etc.), gases like
sour gas or bio gas with high H 2 S content
Measuring ranges  Volumetric flow, a. c. 4 … 400 m3/h / 1,600 … 100,000 m3/h
Measuring ranges depend on nominal pipe size
Repeatability < 0.1 % of the measured value
Accuracy

2-path version 1 :

4-path version 2 :

4-path version 2 :

4-path version 2 :

Error limits
≤ ± 1 %
≤ ± 0.5 %
Dry calibrated≤ ± 0.2 %
After flow calibration and adjustment with constant factor
≤ ± 0.1 %
After flow calibration and adjustment with polynomial or piecewise correction2
In the range Q t … Q max with straight 20D/3D inlet/outlet section or with 10D/3D flow conditioner2
In the range Q t … Q max with undisturbed 10D/3D inlet/outlet section or with 5D/3D flow Conditioner
Diagnostics functions: Integrated device diagnosis and extended diagnosis via MEPAFLOW600 CBM software
Gas temperature: ––40 °C … +180 °C,–194 °C … +280 °C
Operating pressure: 0 bar (g) … 250 bar (g)
On request: Up to 450 bar (g)
Nominal pipe size 2 ” … 48 ”
(DN 50 … DN 1200)
Ambient temperature ATEX, CSA:

IECEx:

–40 °C … +60 °C,–40 °C … +70 °C Optional,–50 °C … +70 °C
Storage temperature –40 °C … +70 °C
Ambient humidity ≤ 95 %
Relative humidity
Conformities: AGA-Report No. 9
API 21.1
OIML D11
OIML R137-1
ISO 17089-1
BS 7965
Pattern approval: MID, PTB, NMi, Measurement Canada, GOST …
Ex-approvals IECEx,ATEX,NEC/CEC (US/CA) Gb/Ga Ex d e ib [ia Ga] IIA T4, Gb/Ga Ex d e ib [ia Ga] IIC T4
Ultrasonic transducers intrinsically safe
II 1/2G Ex de ib [ia] IIA T4
II 1/2G Ex de ib [ia] IIC T4
Ultrasonic transducers intrinsically safe
Class I, Division 1, Groups B, C, D T4
Class I, Division 2, Groups A, B, C, D T4
Class I, Division 1, Group D T4
Class I, Division 2, Group D T4
Ultrasonic transducers intrinsically safe
Electrical safety CE
Enclosure rating IP 65 / IP 66 / IP 67
Analog outputs 1 output:
4 … 20 mA, 200 Ω
Active/passive, electrically isolated
Digital outputs 3 outputs:30 V, 10 mA
Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), f max = 6 kHz(scalable
Interfaces RS-485 (2x, for configuration, output of measured values and diagnosis)
Bus protocol Modbus ASCII,Modbus RTU HART
Operation Via meter display and software MEPAFLOW600
Dimensions (W x H x D) See dimensional drawings
Weight Depending on device version
Material in contact with media Low temperature carbon steel, stainless steel, duplex steel
Electrical connection 12 … 28.8 V DC With active current output: 15 … 28.8 V DC≤ 1 W