Technical Data:

Approvals NFPA 1994 US requirements for protective clothing for
EN 943-2 European requirements for protective clothing for fire brigades
EN 943-1 European requirements for protective clothing for industrial applications
SOLAS II-2, Reg.19 Requirements for use on seagoing vessels
ISO 16602 1 International requirements for chemical protective suits
Temperatures -22 ̊F to 140 ̊F (-30 °C to +60 °C) During use
-4 ̊F to 77 ̊F (-20 °C to +25 °C) In storage
Weight Approx. 6.6 lbs. (3.0 kg)
Approx. 7.7 lbs. (3.5 kg) With Dräger Air-Connect
 1.CPS 5900 without Dräger Air-Connect is approved accord. to ISO 16602.
2.Lower temperatures down to -60 °C are possible on short-term exposure. Observe operating temperatures of the respiratory
protective equipment!

Chemical tests:

Chemical Breakthrough time in min* Chemical Breakthrough time in min* Chemical Breakthrough time in min*
Aceton >480 Ethyl acetate >480 Sarine (GB) >480
Acetonitrile >480 Ethylene oxide >480 Sodium hydroxide
40%
>480
Ammonia >480 Hydrogen chloride >480 Soman (GD) >480
1,3 Butadiene >480 Lewisite (L) >480 Sulfuric acid 96% >480
Carbon disulfide >480 Methanol >480 Tetrachlorethylene >480
Chlorine >480 Methyl Chloride >480 Tetrahydrofurane >480
Dichloromethane >480 Mustard gas (HD) >480 Toluene >480
Diethylamine >480 n-heptane >480 VX >480
* Breakthrough time according to EN 943-2:2002
The continuously updated database Dräger VOICE is available to stay informed about chemical resistances: www.draeger.com/voice.