Special Features:
- Corrosion-resistant
- 100 % lubricant-free
- Gas-tight
- Maintenance-free
- Long service life
- Ex versions suitable for mounting in zone 1 IIC T3 areas
- Ex versions suitable for gases of zone1 IIC T3
- A wide variety of connections available
- Also with integrated bypass valve in the pump head to adjust the pump capacity
Technical Data:
Bellows pump | MP-F05 | MP-F05/R | MP-F10 | MP-F10/R |
Integrated needle valve | No | Yes | No | Yes |
Part No. 230 V 50 Hz | 05P1000 | 05P1010 | 05P1005 | 05P1015 |
Part No. 115 V 60 Hz | 05P1000a | 05P1010a | 05P1005a | 05P1015a |
Voltage tolerance | In accordance with IEC 60034-1 Voltage ±5 % Frequency ±2 % | |||
Degree of protection | IP55 EN 40050 | |||
Capacity max. | 320 Nl/h (approx. 5 Nl/min)with a counter pressure of ±50 mbar on the vacuum and pressure side | 600 Nl/h (approx. 10 Nl/min)with a counter pressure of ±50 mbar on the vacuum and pressure side | ||
Operating pressure | Max. 0.4 – 2.5 bar abs. | Max. 0.3 – 2.5 bar abs. | ||
Gas sample temperature | -30 to +140 °C [-22 to +284 °F] | |||
Ambient temperature | +10 to +50 °C/0 to +50 °C [50 to 122 °F/32 to 122 °F] for dry sample gas | |||
Storage temperature | -20 to +60 °C [-4 to +140 °F] | |||
Current consumption 230 V/115 V | 230 V : 0.35 A/115 V : 0.63 A | |||
Power consumption | 65W | |||
cos φ | 230 V : 0.96/115 V : 0.99 | |||
Gas connections | G1/4″ i DIN ISO 228/1 | |||
Material of sample contacting parts | PTFE, PFA, FEP, (+PVDF for type /R) | |||
Operating mode | 100 % continous duty, starting of the pump only without pressure | |||
Electrical equipment standard | EN 60204-1 | |||
Weight | 4.7 kg [10.36 lb] | |||
Options | ||||
05P1050 | Mounting bracket with 4 anti-vibration pads for bellows pump MP-F | |||
05P1060 | Extra charge for upper pump head of bellows pump MP-F made out of stainless steel | |||
05P1070 | Extra charge for upper pump head of bellows pump MP-F../R made out of stainless steel with needle valve made out of PVDF |
Technical DataVersion:
Bellows pump | MP-F05 | MP-F05/R | MP-F10 | MP-F10/R |
Integrated needle valve | No | Yes | No | Yes |
Part No. 230 V 50 Hz | 05P1100 | 05P1110 | 05P1105 | 05P1115 |
Part No. 115 V 60 Hz | 05P1100a | 05P1110a | 05P1105a | 05P1115a |
Voltage tolerance | In accordance with IEC 60034-1 Voltage ±5 % Frequency ±2 % | |||
Degree of protection | IP55 EN 40050 | |||
Capacity max. | 320 Nl/h (approx. 5 Nl/min)with a counter pressure of ±50 mbar on the vacuum and pressure side | 600 Nl/h (approx. 10 Nl/min)with a counter pressure of ±50 mbar on the vacuum and pressure side | ||
Operating pressure | Max. 0.4 – 2.5 bar abs. | Max. 0.3 – 2.5 bar abs. | ||
Marking | II 2 G c IIC T3 IBExU 15 ATEX B 005 X | |||
Gas sample temperature | -20 to +50 °C [-4 to +122 °F] | |||
Ambient temperature | +10 to +50 °C/0 to +50 °C [50 to 122 °F/32 to 122 °F] for dry sample gas | |||
Storage temperature | -20 to +60 °C [-4 °F to +140 °F] | |||
Current consumption 230 V/115 V | 230 V : 0.88 A/115 V : 1.78 A | |||
Power consumption | 90W | |||
cos φ | 230 V : 0.83/115 V : 0.95 | |||
Gas connections | G1/4″ i DIN ISO 228/1 | |||
Material of sample contacting parts | PTFE, PFA, FEP, (+PVDF for type /R) | |||
Operating mode | 100 % continous duty, starting of the pump only without pressure | |||
Electrical equipment standard | EN 60204-1, EN 13463-1: 2009, EN 13463-5: 2011, EN 60079-0:2012 + A11:2013 | |||
Weight | 230 V : 8.55 kg [18.85 lb]/ 115 V : 7.75 kg [17.09 lb] | |||
Options | ||||
05P1050 | Mounting bracket with 4 anti-vibration pads for bellows pump MP-F | |||
05P1060 | Extra charge for upper pump head of bellows pump MP-F made out of stainless steel | |||
05P1070 | Extra charge for upper pump head of bellows pump MP-F../R made out of stainless steel with needle valve made out of PVDF |